Tx Base Time

(Conventional Emergency Profiles, MDC)

HGDefinitionPort.jpg

Selects a number used by the radio to calculate the amount of time that the radio automatically keys-up in the MDC Emergency Remote Monitor mode. Once this transmit time has expired, the radio then de-keys for the amount of time defined by the Rx Base Time. This feature applies for the current Conventional Emergency Profile. Time is in seconds.

HGImportantNote.jpg

 

The radio uses the Tx Multiplier value (delivered to the radio within an Emergency Call Acknowledgement "Ack", or within a dispatcher sent Remote Monitor Command) multiplied by this Tx Base Time to determine the amount of Emergency Remote Monitor transmission time.

 

And if the Global Multiplier (delivered to the radio within an Emergency Call Acknowledgement "Ack", or within a dispatcher sent Remote Monitor Command) is set to "True", this calculated transmission time is doubled.

HGAccessedOnly.jpg

When the Emergency Type field is set to "Alarm and Call", and

when the radio is model / option capable.

HGSelections.jpg

Minimum

Maximum

Increments

10 sec

120 sec

10 sec

IconSmallNote.png

sec = seconds

GoArrow.jpg

Go to the MDC Page